FDA GMP incoming inspection: What to check before you start manufacturing medical devices 

Before any product leaves your production line, your organization must prove that every quality process works as intended. FDA GMP readiness goes beyond inspection. It builds a culture focused on control and traceability. Performing a proper incoming inspection ensures materials meet specifications before production.

Whether you are a startup preparing for your first launch or a contract manufacturer expanding new lines, readiness starts long before equipment activation. The FDA expects a structured, documented, and functional Quality Management System (QMS) aligned with both global standards and domestic regulations.

This guide outlines every pre-production checkpoint — from QMS foundations and design transfer to process validation (IQ, OQ, PQ), supplier control, and mock audits. Each section helps manufacturers identify and correct compliance gaps before official inspection.

Proactive companies, such as Rexmed Health Inc., have maintained readiness for decades by integrating compliance into everyday operations. Their approach demonstrates that FDA expectations can be met efficiently when systems are built for consistency, not just on inspection day.

QMS foundation and regulatory mapping for incoming inspection

A mature QMS is the backbone of regulatory compliance. It defines how your company maintains control over product quality, manages change, and addresses risk. Integrating a consistent incoming inspection process is essential to verify materials before they enter production.

ISO 13485 alignment to 21 CFR 820 (QSR/QMSR-Aligned)

Your first task is to align your quality system with ISO 13485 and map it to 21 CFR Part 820, with a transition to the QMSR rule soon. This alignment demonstrates readiness for both FDA and global market audits.

Your quality manual should outline the scope, interaction, and hierarchy of all processes. Top-tier SOPs, including document control, nonconformity (NC), CAPA, internal audits, and management reviews, must be implemented and actively utilized. Every record should prove that procedures are followed daily by the Operations team, manufacturing the product

When auditors visit, they often ask, “Show me how you use this.” Have logbooks, training records, and audit reports ready as evidence of use. Avoid systems that exist only on paper. FDA inspectors can easily detect when a QMS lacks operational life.

Mock audits at this stage can reveal missing linkages, outdated forms, or untrained personnel. Treat these findings as opportunities for correction before official scrutiny. A well-structured QMS not only satisfies auditors but also drives consistent product quality.

Design transfer & technical file completeness

Before products reach the manufacturing floor, every design element must translate into clear, controlled documentation. Design transfer ensures that technical data, risk analyses, and validation results move seamlessly from R&D to the production floor.

DMR readiness and DHF/DHR linkages

Design transfer is where design intent becomes a manufacturable reality. The Design Master Record (DMR) should be complete, validated, and directly tied to your Design History File (DHF) and Device History Record (DHR). These linkages demonstrate that production aligns with approved design and risk management outcomes.

Each component must have defined material specifications, acceptance criteria, and supplier verification data. Review labeling and UDI controls to confirm that product identifiers remain accurate throughout distribution.

Packaging plays a critical role. Validate materials and sealing parameters in accordance with ISO 11607 to ensure sterile barrier integrity and consistent performance. Shelf-life studies should confirm that product quality endures through expiry.

Finally, evaluate your change control process. Each modification to design, supplier, or process must have a documented rationale and risk assessment. This prevents uncontrolled variation that could trigger regulatory findings or product recalls.

Process Validation Plan (IQ/OQ/PQ)

A robust process validation IQ/OQ/PQ framework is the heart of manufacturing readiness. It ensures that every process consistently produces compliant products under real-world conditions.

Identifying special processes and critical parameters

Start by listing all special processes — steps where quality cannot be fully verified by inspection alone. These include welding, sealing, and validation of EtO gamma-steam sterilization. Define the parameters that influence safety and performance, and plan validation accordingly.

Your validation master plan (VMP) should include:

  • IQ (Installation Qualification). Confirms that equipment is installed correctly and meets specifications.
  • OQ (Operational Qualification). Establishes operational limits and ensures the process functions within defined tolerances.
  • PQ (Performance Qualification). Demonstrates consistent performance using trained operators, production materials, and real conditions.

Each validation run must be traceable to approved protocols and reports. Include gage studies (MSA) to confirm your measurement systems are reliable, and equipment qualification records to verify accuracy.

Maintenance and calibration programs must also be active and documented. The FDA frequently inspects these records to confirm that the instruments used in validation are within tolerance limits.

Supplier controls and traceability

Strong supplier management protects your manufacturing process from variability and external risk. Weak supplier oversight is one of the most frequent FDA findings, often categorized as major nonconformance.

Approved supplier lists and qualifications

Establish a controlled approved supplier list (ASL) with clear qualification, monitoring, and re-evaluation criteria. Keep records of supplier audits, certificates, and performance metrics.

For high-risk materials, conduct onsite audits or request detailed validation reports. When suppliers change sub-suppliers or processes, your change control must capture and evaluate the impact before acceptance.

Incoming inspection and lot traceability

Your incoming inspection process acts as the first safeguard in the production process. It verifies that materials meet specifications before use, preventing defective inputs from entering the system.

Lot and serial tracking must be seamless. Trace every component from receipt through final product release. Integrate electronic records and signatures that comply with 21 CFR Part 11 to ensure data integrity.

In practice, reliable incoming inspection and traceability systems enable faster investigations, fewer deviations, and higher customer confidence. They also strengthen vendor partnerships in the supply chain by building mutual accountability.

People readiness & mock audit

Even with perfect documentation, your team determines audit success. FDA inspectors observe behavior as much as they review procedures. People’s readiness shows whether compliance is part of your daily culture.

Training matrices and competence records

Develop training matrices that outline which procedures apply to each role. Every operator, engineer, and quality associate must have completed training and assessments for relevant SOPs and equipment. It is critical to keep records signed and dated.

Competency evaluations should go beyond attendance. Use hands-on demonstrations or written tests to confirm understanding. Retain CAPA and nonconformance examples that show how your team addresses real problems.

Batch Record Review and Internal Audit

Before every product release, conduct a detailed review of the batch record. Check entries for completeness, accuracy, and authorized signatures. Any correction must follow documented procedures with traceable initials and dates.

Perform internal audits as a rehearsal for FDA inspections. Simulate document requests, line tours, and interviews. Document every finding and resolve them through a corrective action plan with specific owners and target dates.

Mock audits often uncover missing forms, uncontrolled revisions, or weak root cause analysis. Correcting them early builds confidence and demonstrates a proactive culture of quality.

Ultimately, mock audits transform compliance into a habit. Teams learn how to respond calmly, find documents quickly, and explain their processes clearly.

Final takeaway

Getting FDA GMP-ready takes ongoing effort. It means keeping systems aligned, training staff, and checking that processes work correctly. Starting with a thorough incoming inspection and following through with process validation, IQ/OQ/PQ helps ensure every step delivers consistent quality.

Many teams find that early preparation leads to smoother approvals and fewer production problems. It also strengthens trust with regulators and clients.